Metabolic Solutions offers
a service for the measurement and analysis of
stable isotopes (13C, deuterium oxide, 15N, oxygen
18) in a state-of-the-art mass spectrometry and
HPLC laboratory. Since 1990, Metabolic Solutions
has provided stable isotope measurements to over
five hundred researchers worldwide. Included among
our clients are most of the top 50 pharmaceutical
companies (see client list).
These clients recognize Metabolic Solutions for
its strict compliance to current Good Laboratory
Practices and trust us to produce the quality
of work necessary for submission to regulatory
agencies like the Food and Drug Administration.
The following are some of the most common analytical
services we provide: |
| |
Isotope Ratio Mass Spectrometry
(IRMS) |
| Stable Isotope Analysis |
Substrate |
Optimal sample volume required |
Minimum sample volume required |
Precision of the Instrument |
| 13CO2 |
CO2 Gas or
Blood
|
2-5% in 10 ml Exetainer
tube*
|
0.5% in 10 ml Exetainer
tube*
|
0.2 SD
|
| Deuterium (D2O) |
Body Fluids
|
1 ml
|
50 µl single measurement
|
2% SD
|
| H2O-18 |
Body Fluids
|
0.5 ml
|
50 µl
|
0.4 SD
|
| 15N Combustion |
Solids & dissolved
solids
|
10 mg N
|
0.1 mg N in combustion
capsule
|
Instrument at 0.4 SD,
depending on homogeneity
|
| 15N Ammonia Combustion |
Urine
|
2 ml
|
1 ml
|
Instrument at 0.4 SD
|
|
15N Urea Combustion
|
Urine & Plasma
|
2 ml
|
1 ml
|
Instrument at 0.4 SD
|
| 13C Combustion |
Solids & dissolved
solids, some liquids possible
|
10 mg C
|
0.1 mg C in combustion
capsule
|
Instrument at 0.4 SD,
depending on homogeneity
|
|
13C Glucose Combustion
|
Plasma
|
2 ml
|
0.5 ml one shot
|
Instrument at 0.2 SD
|
|
| |
Gas Chromatography/Mass
Spectrometry (GC/MS) |
| Analysis |
Substrate |
Optimal sample volume required |
Minimum sample volume required |
Precision of the Instrument at
Optimal Levels |
| 13CGlucose |
Plasma
|
300 µl
|
50 µl
|
0.2 % SD
|
| 6,6 D2Glucose
|
Plasma
|
300 µl
|
50 µl
|
0.2 % SD
|
| D5Glycerol |
Plasma
|
500 µl
|
100 µl
|
0.2 % SD
|
| 13CKIC |
Plasma
|
400 µl
|
100 µl
|
0.2 % SD
|
| 13CLeucine |
Plasma
|
400 µl
|
100 µl
|
0.2 % SD
|
| 15NNitrate |
Plasma
|
1000 µl
|
500 µl
|
0.2 % SD
|
|
| |
High Performance Liquid
Chromatography (HPLC) |
| Analysis |
Substrate |
Optimal sample volume
required |
Minimum sample volume
required |
Precision of the Instrument |
|
Sodium Bromide (NaBr)
|
Body Fluids
|
200 µl
|
75 µl
|
5% SD
|
|
| |
Liquid Scintillation Counting |
| Analysis
|
Substrate
|
Optimal sample volume required |
Minimum sample volume required |
Precision of the Instrument |
|
14CO2
|
Breath
|
2 mmol of CO2
|
1 mmol of CO2 |
Chi-square determined daily
using unquenched standards.
|
|
| |
* Exetainer tubes for storing
gas specimens are available by calling Metabolic
Solutions (603) 598-6960. |
Metabolic Solutions,
Inc., 460 Amherst Street, Nashua, NH 03063
Privacy
Policy
|