Stable Isotope Analytical Services


Metabolic Solutions offers a service for the measurement and analysis of stable isotopes (13C, deuterium oxide, 15N, oxygen 18) in a state-of-the-art mass spectrometry and HPLC laboratory. Since 1990, Metabolic Solutions has provided stable isotope measurements to over five hundred researchers worldwide. Included among our clients are most of the top 50 pharmaceutical companies (see client list). These clients recognize Metabolic Solutions for its strict compliance to current Good Laboratory Practices and trust us to produce the quality of work necessary for submission to regulatory agencies like the Food and Drug Administration.

The following are some of the most common analytical services we provide:

 

Isotope Ratio Mass Spectrometry (IRMS)

Stable Isotope Analysis Substrate Optimal sample volume required Minimum sample volume required Precision of the Instrument
13CO2
CO2 Gas or Blood
2-5% in 10 ml Exetainer tube*
0.5% in 10 ml Exetainer tube*
0.2 SD
Deuterium (D2O)
Body Fluids
1 ml 
50 µl single measurement
2% SD
H2O-18
Body Fluids
0.5 ml
50 µl 
0.4 SD
15N Combustion
Solids & dissolved solids
10 mg N
0.1 mg N in combustion capsule
Instrument at 0.4 SD, depending on homogeneity
15N Ammonia Combustion
Urine
2 ml
1 ml
Instrument at 0.4 SD
15N Urea Combustion
Urine & Plasma
2 ml
1 ml
Instrument at 0.4 SD
13C Combustion
Solids & dissolved solids, some liquids possible
10 mg C
0.1 mg C in combustion capsule
Instrument at 0.4 SD, depending on homogeneity
13C Glucose Combustion
Plasma
2 ml
0.5 ml one shot
Instrument at 0.2 SD
 

Gas Chromatography/Mass Spectrometry (GC/MS)

Analysis Substrate Optimal sample volume required Minimum sample volume required Precision of the Instrument at Optimal Levels
13CGlucose
Plasma
300 µl
50 µl
0.2 % SD
6,6 D2Glucose

Plasma
300 µl
50 µl
0.2 % SD
D5Glycerol
Plasma
500 µl
100 µl
0.2 % SD
13CKIC
Plasma
400 µl
100 µl
0.2 % SD
13CLeucine
Plasma
400 µl
100 µl
0.2 % SD
15NNitrate
Plasma
1000 µl
500 µl
0.2 % SD
 

High Performance Liquid Chromatography (HPLC)

Analysis Substrate Optimal sample volume required Minimum sample volume required Precision of the Instrument
Sodium Bromide (NaBr)
Body Fluids
200 µl
75 µl
5% SD
 

Liquid Scintillation Counting

Analysis

Substrate

Optimal sample volume required Minimum sample volume required Precision of the Instrument
14CO2
Breath
2 mmol of CO2
1 mmol of CO2
Chi-square determined daily using unquenched standards.
 

* Exetainer tubes for storing gas specimens are available by calling Metabolic